ME Labs, Inc. 719-520-5323 |
|
|
|
ME Labs, Inc. | 1-719-520-5323 | Example Program - LTCX.pbpPICBASIC PRO program to read LTC1298 ADC.' Name : LTCX.pbp
' Compiler : PICBASIC PRO Compiler 2.6
' Assembler : PM or MPASM
' Target PIC : 40-pin 16F877A, 18F452 or similar
' Hardware : LAB-X1 Experimenter Board
' Oscillator : 4MHz external crystal
' Keywords : SHIFTIN, SHIFTOUT, LCDOUT
' Description : PICBASIC PRO program to read LTC1298 ADC.
'
' Define LOADER_USED to allow use of the boot loader.
' This will not affect normal program operation.
Define LOADER_USED 1
' Define LCD pins
Define LCD_DREG PORTD
Define LCD_DBIT 4
Define LCD_RSREG PORTE
Define LCD_RSBIT 0
Define LCD_EREG PORTE
Define LCD_EBIT 1
Include "modedefs.bas"
' Alias pins
CS Var PORTC.5 ' Chip select
CK Var PORTC.3 ' Clock
DI Var PORTA.2 ' Data in
D0 Var PORTC.1 ' Data out
' Allocate variables
addr Var Byte ' Channel address / mode
x Var Word
y Var Word
z Var Word
result Var Word
High CS ' Chip select inactive
ADCON1 = 7 ' Set PORTA, PORTE to digital
Low PORTE.2 ' LCD R/W line low (W)
Pause 100 ' Wait for LCD to start
Goto mainloop ' Skip subroutines
' Subroutine to read a/d convertor
getad:
CS = 0 ' Chip select active
' Send address / mode - Start bit, 3 bit addr, null bit]
Shiftout DI, CK, MSBFIRST, [1\1, addr\3, 0\1]
Shiftin D0, CK, MSBPRE, [result\12] ' Get 12-bit result
CS = 1 ' Chip select inactive
Return
' Subroutine to get x value (channel 0)
getx:
addr = $05 ' Single ended, channel 0, MSBF high
Gosub getad
x = result
Return
' Subroutine to get y value (channel 1)
gety:
addr = $07 ' Single ended, channel 1, MSBF high
Gosub getad
y = result
Return
' Subroutine to get z value (differential)
getz:
addr = $01 ' Differential (ch0 = +, ch1 = -), MSBF high
Gosub getad
z = result
Return
mainloop:
Gosub getx ' Get x value
Gosub gety ' Get y value
Gosub getz ' Get z value
Lcdout $fe, 1, "x=", #x, " y=", #y, " z=", #z ' Send values to LCD
Pause 100 ' Do it about 10 times a second
Goto mainloop ' Do it forever
End
Download the program file. |
|