ME Labs, Inc. 719-520-5323 |
|
|
|
ME Labs, Inc. | 1-719-520-5323 | Example Program - SPIX.pbpPICBASIC PRO program to read and write to SPI SEEPROMs Writes to the first 16 locations of an external serial EEPROM. Then reads first 16 locations back and send to LCD repeatedly Note: for SEEPROMs with word-sized address.' Name : SPIX.pbp
' Compiler : PICBASIC PRO Compiler 2.60
' Assembler : PM or MPASM
' Target PIC : 40-pin 16F887
' Hardware : LAB-X1 Experimenter Board
' Oscillator : 4MHz external crystal
' Keywords : LCDOUT, SHIFTIN, SHIFTOUT
' Description : PICBASIC PRO program to read and write to SPI SEEPROMs
' Writes to the first 16 locations of an external serial EEPROM. Then
' reads first 16 locations back and send to LCD repeatedly Note: for
' SEEPROMs with word-sized address.
'
' Define LCD registers and bits
Define LCD_DREG PORTD
Define LCD_DBIT 4
Define LCD_RSREG PORTE
Define LCD_RSBIT 0
Define LCD_EREG PORTE
Define LCD_EBIT 1
Include "modedefs.bas"
CS Var PORTA.5 ' Chip select pin
SCK Var PORTC.3 ' Clock pin
SI Var PORTC.4 ' Data in pin
SO Var PORTC.5 ' Data out pin
addr Var Word ' Address
B0 Var Byte ' Data
TRISA.5 = 0 ' Set CS to output
ANSEL = %00000000 ' Make PORTA and PORTE digital
ANSELH= %00000000 ' Make PORTA and PORTE digital
Low PORTE.2 ' LCD R/W line low (W)
Pause 100 ' Wait for LCD to start up
For addr = 0 To 15 ' Loop 16 times
B0 = addr + 100 ' B0 is data for SEEPROM
Gosub eewrite ' Write to SEEPROM
Pause 10 ' Delay 10ms after each write
Next addr
mainloop:
For addr = 0 To 15 ' Loop 16 times
Gosub eeread ' Read from SEEPROM
Lcdout $fe,1,#addr,": ",#B0 ' Display
Pause 1000
Next addr
Goto mainloop
' Subroutine to read data from addr in serial EEPROM
eeread:
CS = 0 ' Enable serial EEPROM
Shiftout SI, SCK, MSBFIRST, [$03, addr.byte1, addr.byte0] ' Send read command and address
Shiftin SO, SCK, MSBPRE, [B0] ' Read data
CS = 1 ' Disable
Return
' Subroutine to write data at addr in serial EEPROM
eewrite:
CS = 0 ' Enable serial EEPROM
Shiftout SI, SCK, MSBFIRST, [$06] ' Send write enable command
CS = 1 ' Disable to execute command
CS = 0 ' Enable
Shiftout SI, SCK, MSBFIRST, [$02, addr.byte1, addr.byte0, B0] ' Send address and data
CS = 1 ' Disable
Return
End